What was found
APU EXTERNAL AREA NEXT TO TAIL CONE (STA. 1992) SHOWS EVIDENCE OF CORROSION. INSTALLED BOND ASSY SKIN LOWER PANEL 1 EA AT APU EXTERNAL AREA NEXT TO TAIL CONE BS 1992 IAW B757-200 SRM 51-40-02-0G-0
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU EXTERNAL AREA NEXT TO TAIL CONE (STA. 1992) SHOWS EVIDENCE OF CORROSION. INSTALLED BOND ASSY SKIN LOWER PANEL 1 EA AT APU EXTERNAL AREA NEXT TO TAIL CONE BS 1992 IAW B757-200 SRM 51-40-02-0G-0