What was found
FOUND AFT CARGO FLOOR PANEL CRACKED. IAW SRM 53-00-50-2R-0 REV. 95, CUT OUT THE DAMAGE AND CLEANED. BONDED THE REPAIR PLIES WITH RESIN CURED AT 170F FOR 2 HOURS WITH A MINIMUM VACUUM OF 20 IN/HG IAW SRM 53-00-50-2R-0, REV 95.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND AFT CARGO FLOOR PANEL CRACKED. IAW SRM 53-00-50-2R-0 REV. 95, CUT OUT THE DAMAGE AND CLEANED. BONDED THE REPAIR PLIES WITH RESIN CURED AT 170F FOR 2 HOURS WITH A MINIMUM VACUUM OF 20 IN/HG IAW SRM 53-00-50-2R-0, REV 95.