What was found
STRINGER CRACK, FWD SIDE OF STA 740 S-19L (LEVEL 1) (REPAIR), RII COMPLETED FOR PERFORMED SRM 53-20-03-2R-5 REV.49 AND EGAT WORK SHEET NO.60592 STEP 19.COMPLETED SHOT PEEN FOR REPAIR CLIP , PERFORMED SPWPS-SP-003 REV.00, VALIDATE THE LIST OF REPAIR MATERIALS WITH PO TRACEABILITY IS DOCUMENTED ON THE FAULT THAT IS ASSOCIATED. INCLUDING FASTENERS, RAW MATERIAL, AND COMPONENTS/PARTS. 44. VERIFY REPAIR IS ACCOMPLISHED PER REQUIREMENTS.