What was found
FOUND PANEL 192B TO HAVE LEADING EDGE ERRODED & DELAMINATED. AW SRM 53-00-70-2R-1, REF SRM 51-70-05-2R-2 & SRM 51-80-03-0G-0, REV 49. PERFORMED REPAIR, REMOVED EROSION MATERIALS & CLEAN. MEASURE THE DAMAGE AREA (L:4", W:3", AT FWD EDGE CORNER & L:14.5", W:0.5", 15" FROM OTBD EDGE, AT FWD EDGE). BONDED THE REPAIR PLIES WITH FILM ADHESIVE CURED AT 260 F FOR 130 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG. BONDED THE FOIL WITH FILM ADHESIVE CURED AT 260 F FOR 130 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG. DRILLED THE FASTENER HOLES ON PANEL NR 192B IAW SRM 51-40-05-0G, REV 49.