What was found
MAJOR REPAIR. CENTER FUSELAGE BASE FRAME FITTING FR45 LH SIDE HAS SIGNS OF CRACK. AFTER FURTHER EVALUATION FOUND CRACK LENGTH IS 0.100". ACCOMPLISHED REPAIR IAW EO 46789-JIC 7 AND EO-46789-REQ 6 (APPX J).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAJOR REPAIR. CENTER FUSELAGE BASE FRAME FITTING FR45 LH SIDE HAS SIGNS OF CRACK. AFTER FURTHER EVALUATION FOUND CRACK LENGTH IS 0.100". ACCOMPLISHED REPAIR IAW EO 46789-JIC 7 AND EO-46789-REQ 6 (APPX J).