What was found
MAIN DECK FLOOR STRUCTURE, FLOOR BEAM AT STA 1540 HAS CORROSION BETWEEN BL0 & RBL25 (UPPER AND LOWER SIDE). REMOVED CORROSION ON MAIN DECK FLOOR STRUCTURE, FLOOR BEAM AT STA 1540 BETWEEN BL0 & RBL25 IAW , SRM 51-10-0. APPLIED SURFACE PROTECTION ON AREAS REWORKED IAW SRM 51-20-01, AMM 51-21-15.