What was found
MAIN DECK FLOOR STRUCTURE, FLOOR BEAM HAS CORROSION AT STA 1540 BETWEEN RBL 25 & RBL 45. REMOVED CORROSION MAIN DECK FLOOR STRUCTURE, FLOOR BEAM AT STA 1540 BETWEEN RBL 25 & RBL 45 IAW SRM 51-10-02, WITHIN LIMITS IAW SRM 53-00-51-1A-1. APPLIED SURFACE PROTECTION ON AREAS REWORKED IAW , SRM 51-20-01, AMM 51-21-15.