What was found
MAIN DECK, FLOOR STRUCTURE WEB HAS CORROSION AT RBL45 BETWEEN STA 1600 & STA 1580 (DOT 64-013). LIGHT SANDING BY HAND SURFACE, LIGHT CORROSION AT MAIN DECK, FLOOR STRUCTURE WEB, RBL45 BETWEEN STA 1600 & STA 1580 FOUND TO BE WITHIN LIMITS IAW SRM 51-10-02-0G-0 STEP 14(1) AND IAW SRM 53-00-51-1A-1 DETAIL VI. RESTORED SURFACE PROTECTION IAW SRM 51-20-01 AND AMM 51-21-15.