What was found
EMERGENCY LIGHTS TEST FAILS, LIGHTS STAY ACTIVATED WHEN TEST IS PREFORMED AT L1 DOOR, THEY DO NOT EXTINGUISH UNTIL PULLING 22VU E28 CB.PERFORMED CONTINUITY CHECK IAW A300 AWM 33-51-03 BETWEEN "TEST EMER" PUSH BUTTON SWITCH 25WL AND 5801VC CONNECTOR LIGHTING CONTROL PANEL 818VU PINS.PERFORMED CRIMPING PIN -R WIRE ID 3351-1090 IAW A300 ESPM 20-40-00-02 AND PERFORMED OPS CHECK GOOD IAW AMM 33-51-00/501 AND CONTINUITY TEST IAW ESPM 20-52-21-11 AND IAW A300 AWM 33-51-03