What was found
INSPECTION TYPE:C, MAIN CARGO PIT STA 940, BETWEEN STRINGER 15R AND 16R, FRAME FREE FLANGE IS GOUGED IN 1 EA AREAS. BLENDED GOUGE AT STA 940. BETWEEN STR 15R AND 16R, ORIGINAL THICKNESS .163 WITH A LOSS OF .021 WTIH .142 REMAINING IS OUT OF LIMITS IAW SRM 53-00-07-1A1. ACCOMPLISHED STEP OF EA FOR EXTENDED LIMITS AIW EA 120236 EO B757-5310-46167-A.