What was found
T/E FLAP DISAGREE ON APPROACH, WHEN FLAPS SELECTED PAST 5. ACCOMPLISHED T/E DISAGREE AND LANDED FLAPS 20. EMERGENCY DECLARED. LANDED WITHOUT INCIDENT. FOUND NR 3 FLAP POSITION TRANSDUCER CONNECTOR LOOSE. SYS CHECKED NORMAL IAW FIM 27-51-00, FIG 105.