What was found
INSPECTION TYPE: D, MAIN DECK BS 740 TENSION TIE FWD CHANNEL TWO HOLES FOUND CRACKED. REPAIRED IAW SRM 53-20-30-2R REPAIR 1 REV 63, HX RS R-53-25-37443-A & EO B747-5310-48484-A, ORIG MATL: BAC1494-206-2024T42, CLASSIFIED AS A MAJOR REPAIR, ACCOMPLISH INITIAL INSP OF THE REPAIR AREA IAW SRM 53-20-30-2R1.