What was found
DURING C CHECK INSPECTION, LT IB FLAP UPPER PART WITH SEVERAL DENTS XW 2.000 - XW 20.000. PERFORMED MAJOR REPAIR IAW SRM 57-2-5 FIG. 1, EO NR 20051013 DATE 06-29-05. REMOVED FASTENERS IAW SRM 51-1-21 PAGE 1, SRM 51-3-0PAGE 1. REMOVED PLATING SEGMENT (DAMAGED) IAW SRM 57-2-5 FIG. 1. PERFORMED NDT INSPECTION IAW NDT SPM PART 06-10-01-001. NO CRACK, CORROSION FOUND. FABRICATED NEW PLATING (ALCLAD 2024 T3 0.050”) + INTERNAL SPLICE (ALCLAD 2024 T3 0.063”) IAW SRM 57-2-5 FIG. 1 (SHEET 1,3), SRM 57-7-1 FIG. 1 ITEM A. CLEANED, TREATED AND PRIMED AREA + NEW PLATING INTERNAL PART IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PAGE 9. INSTALLED REPAIR PARTS IAW SRM. TORQUED IAW SRM 51-3-1.