What was found
DURING ROUTINE C CHECK INSPECTION, LT MLG WW FITTING CRACKED STA 857.125 BETWEN L.23 AND L.24. REMOVED CRACKED FITTING IAW DC-8 SRM 51-1-20D. FABRICATED NEW FITTING IAW ATI REPAIR SPECIFICATION NR 2003-05, DWG DOUG NR 3646772. PERFORMED HEAT TREAMENT IAW DC-8 SRM 51-1-1 PAGES 1, 13, 17. PERFORMED NON-DESTRUCTIVE INSPECTION IAW NDT SPM PART 08-00-02 TO 07. CLEANED, TREATED AND PRIMED AREA, NEW FITTING IAW DC-8 SRM 51-1-8B. INSTALLED NEW FITTING IAW DC-8 SRM 51-3-0, DC-8 51-1-20D AND DC-8 SRM 51-3-1 (TORQUED).