What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LEFT WING NR 2 STUB WING SLOT DOUBLER HAS ELONGATED HOLES AT STATION XS 250.000. REMOVED EXISTING REPAIR DOUBLER. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACKS OR CORROSION FOUND AFTER DAMAGE REMOVAL. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-21, DC8 SRM 51-3-0, DC8 SRM 51-1-20D, DC8 SRM 51-3-1, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, FAA FORM 8110-3, NUMBER 06565 DATED 11-13-06, SEMAN DRAWING, NUMBER ED-4381 DATED 11-09-06, AND SEMAN ENGINEERING ORDER, NUMBER 2006961 DATED 11-13-06.