What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING TRAPEZOIDAL FITTING CRACKED AT STATION 902.000. REMOVED DAMAGED TRAPEZOIDAL SUPPORT FITTING. INSTALLED NEW TRAPEZOIDAL SUPPORT FITTING IAW DOUGLAS DRAWINGS, NUMBER 5750127 AND NUMBER 5750092, DC8 SRM 53-1-0 PAGE 1, DC8 SRM 51-1-21, DC8 SRM 51-3-0, DC8 SRM 51-1-20D AND DC8 SRM 51-3-1.