What was found
FLOOR BEAM FLOOR BOARD LANDING BETWEEN FS 409.00 TO FS 409.00 + 37 AT RBL 9.0 BEYOND LIMITS OF REO 601R-53-00-005. (FILED CLOSED) PERFORMED REPAIR OF FLOOR BEAM FROM FS 409.00 TO FS 409.00 + 37 WITH REFERENCE TO REO 601R-53-00-027 REV "D" DATED 26-NOV-2009. PERFORMED EDDY CURRENT INSPECTION OF CUT LINES WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.