What was found
CORROSION ON LH PRESSURE FLOOR ASSY WL73.00 BETWEEN FS409 + 128 -TO FS559.00 AND BETWEEN LBL36.00 AND LBL47.00. (FILED CLOSED) BLENDED CORROSION ON LH PRESSURE FLOOR SILL ASSY WL73.00 BETWEEN FS409 + 128 TO FS559.00 AND BETWEEN LBL36.00 AND LBL47.00 WITH REFERENCE TO SRM 51-21-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE ACCEPTABLE PER REO 601R-53-41-666 REV "-C" DATED 2012-11-06. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. COMPLIED WITH REO 601R-53-41-666 REV "-C" DATED 2012-11-06. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.