What was found
CORROSION ON RH CABIN FLOOR SILL ASSY WL73.00 BETWEEN FS559.00 TO FS 559.00 + 16 AND BETWEEN RBL 41.75 (FILED CLOSED) COMPLIED WITH REO 601R-53-51-699 DATED: 2025-01-15 REV - - TEMPORARY DISPOSITION FOR BLENDED CORROSION DAMAGE TO FLOOR SILL STRUCTURE BTW FS559.00 FS559.00+16 AND AT BL41.75, RHS. REFERENCE CHILD FOR MCI'S CREATED FOR PERMANENT REPAIR AND VISUAL REINSPECTS. COMPLETED CORROSION FINDINGS REPORT. COMPLIED WITH TASK CARD 51-900-1003-SKY AND M337.