What was found
RH ELECTRIC BOOST PUMP SATELLITE HOLE # 9 ON LOWER AFT WING PLANK HAS TOO MUCH NOISE INDICATION DURING EDDY CURRENT OPEN HOLE INSPECTION. (FILED CLOSED) REPAIRED RH ELECTRIC BOOST PUMP SATELLITE HOLE #9 ON LOWER AFT WING PLANK WITH REFERENCE TO REO 601R-57-21-169 REV "D" DATED 2008-06-23 REPAIR #2. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 6 53-00-097 WITH NO DEFECTS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337.