What was found
FLOOR BEAM, FLOOR BOARD LANDING HAS SURFACE CORROSION BETWEEN FS 409.00 TO 409.00 +112 @ RBL 9.00. (FILED CLOSED) REMOVED CORROSION ON FLOOR BEAM FLOOR BOARD LANDING BETWEEN FS409.00 TO FS409.00 + 112 @ RBL 9.0 WITH REFERENCE TO SRM 51-21-06. PERFORMED UT THICKNESS MEASUREMENT OF BLEND WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF REO 601R-53-00-005 REV "-B" DATED 2011/01/06 BETWEEN FS 409.00 + 37 TO FS 409.00 + 112. FS 409.00 TO FS 409.00 + 37 FOUND TO BE OUT OF LIMITS AND REQUIRES REPAIR - SEE CHILD CAMP FOR CONTINUATION. PERFORMED EDDY CURRENT INSPECTION OF BLENDED AREAS AND WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.