What was found
VCS FAN NOT RUNNING WITH VCS ON. CREW RESET AIRCRAFT ON GROUND AND THE VCS FAN STARTED EMITTING A BURNING SMELL. REPLACED COMPRESSOR DRIVE MOTOR IAW EMB 505 AMM 21-52-01 AND ENVIRO CMM 21-53-18. OPS CHECKS SATISFACTORY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VCS FAN NOT RUNNING WITH VCS ON. CREW RESET AIRCRAFT ON GROUND AND THE VCS FAN STARTED EMITTING A BURNING SMELL. REPLACED COMPRESSOR DRIVE MOTOR IAW EMB 505 AMM 21-52-01 AND ENVIRO CMM 21-53-18. OPS CHECKS SATISFACTORY.