What was found
MECHANICALLY BLENDED CORRODED AREA ON THE LOWER SIDE OF THE EMERGENCY EXIT DOOR. REMOVED CONTOUR RINGS AND FOUND ADDITIONAL CORROSION. BLENDED AREA FOUND UNDER CONTOUR RINGS AND FOUND ONE AREA CORRODED THROUGH. REPLACED THE EMERGENCY EXIT DOOR WITH A NEW ONE.