What was found
MECHANICALLY BLENDED CORRODED AREA FROM THE VERTICAL STABILIZER LH SPAR CLIP, APPROXIMATELY FOUR INCHES BELOW THE MIDDLE RUDDER HINGE, PERFORMED EDDY CURRENT CRACK AND ULTRASONIC THICKNESS INSPECTIONS AND REPORTED TO TEXTRON FOR REPAIR DISPOSITION. CLEANED, TREATED, AND TOP COATED REPAIR AREA PER TEXTRON REPAIR MEMO.