What was found
DURING CLIMB OUT AT APPROX 8000 FT MSL, PILOT NOTICED RT GENERATOR FAILED. PERFORMED POH CHECKLIST ITEMS & TRIED TO RESET GENERATOR WITH THE SAME RESULTS. TOWER ELECTED TO DECLARE AN EMERGENCY . RETURNED & LANDED WITHOUT FURTHER INCIDENT. TROUBLESHOOTING REVEALED RT OVER VOLTAGE RELAY & LT REVERSE CURRENT RELAY DEFECTIVE. R & R BOTH RELAYS. PERFORMED ELEC SYS OPS CHECKS. ALL SYSTEMS CHECKED NORMAL.