What was found
FIRE WARNING LIGHT ILLUMINATED, AND BELL SOUNDED (GLARESHIELD ANNUNCIATOR PANEL) DURING TAKE-OFF ROLL/UPPER CARGO SMOKE DETECTOR. INSPECTED MAIN CARGO COMPARTMENT, NO FIRE, NO SMOKE AND PERFORMED MAIN DECK FIRE AND SMOKE DETECTION SYSTEM TEST IAW IAI SMM 26-16-05 AND 26-16-07, OPS CHECK GOOD.