What was found
DOOR FLIGHT LOCK R1 STATUS MESSAGE. ACTION TAKEN: REMOVED AND REPLACED RELAY K52201 IAW FIM 52-11 TASK 826 AND SWPM 20-81-22, NO HELP. CORROSION FOUND ON R1 DOOR FLIGHT LOCK MECHANISM SPRING. LUBRICATED FLIGHT LOCK MECHANISIM IAW AMM 12-21-20, OPS CHECKED GOOD IAW AMM 52-11-26, STATUS CLEARED.