As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
E2 WILL NOT START, NO FUEL FLOW TO ENGINE, RIGHT FUEL FLOW INDICATOR SHOWS NO FUEL FLOW.......MX REMOVED AND REPLACED E-2 FUEL SHUT OFF VALVE WITH OVERHAULED IAW GARRETT TPA321-11 MAINTENANCE CH 73-10-06. MX ALSO INSTALLED OVERHAULED INDICATOR AND OPS CHECK NORMAL. PERFORMED ENGINE GROUND RUNS AND OPS CHECKS, LEAK CHECK GOOD.