What was found
DURING SCHEDULED C2 INSPECTION PER JOB CARD HC05297 FOUND FS 245 - 345E RH FLOOR PANEL WARPED AND CORRODED AT LBL 16 - 42, WL 146.REPLACED FLOOR PANEL IAW SRM SMP 583-53-40-05. NR 2143.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION PER JOB CARD HC05297 FOUND FS 245 - 345E RH FLOOR PANEL WARPED AND CORRODED AT LBL 16 - 42, WL 146.REPLACED FLOOR PANEL IAW SRM SMP 583-53-40-05. NR 2143.