What was found
DURING SCHEDULED B1 INSPECTION PER JOB CARD HB0521 FOUND RH FLAP TRACK RIB STIFFENER FITTING CRACKED 2.0 IN. IN LOWER FLANGE AT RH OWS 28, FS 598, WL 257.REPLACED FITTING IAW SRM SMP 583 51-70 AND DWG 3325706. NR 0115.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED B1 INSPECTION PER JOB CARD HB0521 FOUND RH FLAP TRACK RIB STIFFENER FITTING CRACKED 2.0 IN. IN LOWER FLANGE AT RH OWS 28, FS 598, WL 257.REPLACED FITTING IAW SRM SMP 583 51-70 AND DWG 3325706. NR 0115.