DURING SCHEDULED C4 INSPECTION PER JOB CARD HC4911 FOUND LT FLOORBEAM CHINE ANGLE CRACKED AT FS 477, LBL 61, WL 140. REPAIR IAW SRM SMP 583 53-40-27. NR 2108.