What was found
DURING SCHEDULED B1 INSPECTION PER JOB CARD HB3201 FOUND LT FS 517 MLG BEAM OUTER CAP CRACKED AT WL 215, LBL 62. REPLACED OUTER CAP IAW DWG 388394 AND SRM SMP 583 51-70. NR 0014.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED B1 INSPECTION PER JOB CARD HB3201 FOUND LT FS 517 MLG BEAM OUTER CAP CRACKED AT WL 215, LBL 62. REPLACED OUTER CAP IAW DWG 388394 AND SRM SMP 583 51-70. NR 0014.