What was found
DURING SCHEDULED B2 INSPECTION IAW JOB CARD HB5302 FOUND RT FS 477 FLOORBEAM END FITTING CRACKED AT RBL 60, WL 146. REPLACED FITTING IAW DWG 356245-19 AND SRM SMP 583 51-70. NR 0027.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED B2 INSPECTION IAW JOB CARD HB5302 FOUND RT FS 477 FLOORBEAM END FITTING CRACKED AT RBL 60, WL 146. REPLACED FITTING IAW DWG 356245-19 AND SRM SMP 583 51-70. NR 0027.