DURING SCHEDULED B-2 CHECK, PER JOBCARD HB5301, FOUND CENTER FUSELAGE EXTERIOR STRUT UPPER FITTING CRACKED AT FS 477 WL 150 RBL 71. FITTING REPLACED IAW SMP583 FIG 51-60 & 51-70. P/N:339394-3.