What was found
DURING SCHEDULED C-8 CHECK PER JOB CARD HC5301, FOUND UNDER DECK FLOORBEAM UPPER CAP TIE DOWN POINT EXFOLIATION CORROSION AT FS 242, WL 146, LBL 56. REPLACED IAW DRAWING 389183.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-8 CHECK PER JOB CARD HC5301, FOUND UNDER DECK FLOORBEAM UPPER CAP TIE DOWN POINT EXFOLIATION CORROSION AT FS 242, WL 146, LBL 56. REPLACED IAW DRAWING 389183.