What was found
DURING SCHEDULED C-9 CHECK PER JOB CARD HC5211, FOUND RAMP DOOR INTERCOSTAL LOWER BEAM WEBS (2EA) & CAPS (2EA), CRACKED AT RS6.1, WL 152, BL 0. FABRICATED AND REPLACED CAPS & WEBS IAW SRM SMP583 51-60 & 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-9 CHECK PER JOB CARD HC5211, FOUND RAMP DOOR INTERCOSTAL LOWER BEAM WEBS (2EA) & CAPS (2EA), CRACKED AT RS6.1, WL 152, BL 0. FABRICATED AND REPLACED CAPS & WEBS IAW SRM SMP583 51-60 & 51-70.