What was found
DURING SCHEDULED C-9 CHECK PER JOB CARD HC5315 FOUND RAMP DOOR INTERIOR INTERCOSTAL BEAM WEB CRACKED AT RAMP STATION 6.1, BL 0, WL 150. REPLACED BEAM WEB IAW SMP583 CHAPTER 51-60 & 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-9 CHECK PER JOB CARD HC5315 FOUND RAMP DOOR INTERIOR INTERCOSTAL BEAM WEB CRACKED AT RAMP STATION 6.1, BL 0, WL 150. REPLACED BEAM WEB IAW SMP583 CHAPTER 51-60 & 51-70.