What was found
DURING SCHEDULED C-11 CHECK, FOUND FLOORBEAM LOWER CAP HAD EXFOLIATION CORROSION BS 577, LBL 10 TO RBL 10, WL 126. REPAIRED BY REPLACEMENT ACCOMPLISHED IAW SMP583, 51-60 AND 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-11 CHECK, FOUND FLOORBEAM LOWER CAP HAD EXFOLIATION CORROSION BS 577, LBL 10 TO RBL 10, WL 126. REPAIRED BY REPLACEMENT ACCOMPLISHED IAW SMP583, 51-60 AND 51-70.