What was found
DURING SCHEDULED C-12 CHECK, UNDER JOB CARD HC5314, FOUND THE RAMP DOOR RT CHINE PLATE WITH EXFOLIATION CORROSION AT RS1.6 AND RS7.6 AT 2 PLACES; RBL50 & RBL60. REPAIR BY REPLACEMENT, ACCOMPLISHED IAW SMP 583, SRM CH51-60 AND 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-12 CHECK, UNDER JOB CARD HC5314, FOUND THE RAMP DOOR RT CHINE PLATE WITH EXFOLIATION CORROSION AT RS1.6 AND RS7.6 AT 2 PLACES; RBL50 & RBL60. REPAIR BY REPLACEMENT, ACCOMPLISHED IAW SMP 583, SRM CH51-60 AND 51-70.