What was found
DURING SCHEDULED C-12 CHECK, UNDER JOB CARD HC5312, FOUND THE UNDERDECK FLOOR SUPPORT L-ANGLE WITH STRESS CORROSION CRACKING AT FS 196 WL146, LBL61 TO RBL61 AROUND ANCHOR NUT HOLES. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP 583, SRM CH51-60 AND CH51-70.