What was found
DURING SCHEDULED C-14 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND RH FS797.0E UNDERFLOOR BULKHEAD TO RING SEGMENT FITTING CRACKED AT RBL61, WL141-143. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 0507. / PSE# 53-40-11, AD 2012-06-09