What was found
DURING SCHEDULED C-15 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND CENTER FUSELAGE BELLY SKIN TO HAVE ELONGATED HOLES AT FS537-577, BL61LT & RT, WL126-145. REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70.