What was found
DURING C CHECK/BRIDGING INSPECTION PER HSP57108, FOUND RMLG FS 583 ACCESS PANEL OPENING DENTED BEYOND LIMITS AT WL 155. REPAIRED IAW SMP 583 51-140-17.