DURING C CHECK/BRIDGING INSPECTION PER HC05297, FOUND CARGO LOWER STRUCTURE FS 597 UPPER BEAM CAP CORRODED AT RBL 40. REPLACED CAP IAW SMP 583 53-40. NR 924.