What was found
DURING C CHECK/BRIDGING INSPECTION - PER HC05297, FOUND RAMP RT CHINE CAP CORRODED AND CRACKED. REPLACED CHINE CAP IAW SMP 583 52-60 AND DWG 354104.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C CHECK/BRIDGING INSPECTION - PER HC05297, FOUND RAMP RT CHINE CAP CORRODED AND CRACKED. REPLACED CHINE CAP IAW SMP 583 52-60 AND DWG 354104.