SDR LYNX00003

Service difficulty report · Sequence Valve · Bombdr DHC8402

Difficulty date
January 8, 2008
Submitted
January 11, 2008
Operation
Air carrier
Aircraft
N507LX
Make and model
Bombdr DHC8402
Aircraft serial
4181
Aircraft time
39 hours, 29 cycles
Part
Sequence Valve
Part number
483025
Part serial
FAH0699
Condition
Sticking
Location
Mlg
Part time
39 hours, 29 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF LT DOOR AMBER LIGHT FAILED TO EXTINGUISH, FOLLOWED QRH PROCEDURE AND EXTENDED GEAR, LT GEAR DOOR AMBER LIGHT STILL DID NOT EXTINGUISH AND RED LT LANDING GEAR WARNING REMAINED ILLUMINATED. AFTER APPROX 5 MINUTES GEAR LOCKED DOWN AND GREEN LT LIGHT ILLUMINATED. FA REPORTED VERY SLOW EXTENSION OF LT GEAR. RETURNED TO DEPARTURE. MAINTENANCE PINNED GEAR AND FLEW AIRCRAFT ON A SPECIAL FLIGHT PERMIT. MAINTENANCE WAS ABLE TO DUPLICATE THE PROBLEM ON THE GROUND, TROUBLESHOT TO THE LT SOLENOID SEQUENCE VALVE, DFDR WAS DOWNLOADED AND CONFIRMED THAT THE LT GEAR TOOK 1 MINUTE AND 8 SECONDS TO EXTEND WHICH IS CONSISTENT WITH A SOLENOID SEQUENCE VALVE STUCK IN THE (OUT OF SEQUENCE) FAULT. MAINTENANCE ALSO CHANGED THE MECHANICAL SEQUENCE VALVE AS A PRECAUTION. PERFORMED GEAR SWING AND LANDING GEAR FUNCTIONED NORMALLY; PERFORMED OPERATIONAL CHECK FLIGHT AND LANDING GEAR FUNCTIONED NORMALLY.