What was found
PILOT & MEDICAL CREW WAS TRANSPORTING A PATIENT WHEN SHORTLY AFTER TAKEOFF THE PILOT HAD ENCOUNTERED A TRANSMISSION CHIP LIGHT INDICATION. PILOT IMMEDIATELY PERFORMED A PRECAUTIONARY LANDING SAFELY. PATIENT WAS TRANSPORTED BY GND. MAINTENANCE WAS NOTIFIED & EN ROUTE WITH SUPPLIES & EQUIPMENT. INSPECTED ALL CHIP DETECTORS & FOUND PASTE ON UPPER DETECTOR. DETECTOR WAS CLEANED, A DRAIN & FLUSH ON THE TRANSMISSION ALONG WITH A FILTER CHANGE WAS PERFORMED IAW BMM PROCEDURES. PERFORMED PENALTY GND RUN, RE-INSPECTED DETECTORS NO DEBRIS NOTED. PAPERWORK COMPLETED. ACFT RETURNED TO SERVICE.