What was found
PILOT AND MEDICAL CREW WERE TRANSPORTING A PATIENT WHEN SHORTLY AFTER TAKEOFF THE PILOT HAD ENCOUNTERED A TRANSMISSION CHIP LIGHT INDICATION. PILOT IMMEDIATELY PERFORMED A PRECAUTIONARY LANDING AT A PARKING LOT. PATIENT WAS TRANSPORTED BY GROUND. MAINTENANCE WAS NOTIFIED AND ENROUTE WITH SUPPLIES AND EQUIPMENT. MAINTENANCE INSPECTED ALL CHIP DETECTORS AND FOUND DEBRIS ON LOWER DETECTOR. DETECTOR WAS CLEANED AND A DRAIN AND FLUSH ON THE TRANSMISSION ALONG WITH A FILTER CHANGE WAS PERFORMED PER BMM PROCEDURES. PERFORMED PENALTY GROUND RUN, RE-INSPECTED DETECTORS NO DEBRIS NOTED. PAPERWORK COMPLETED. ACFT RETURNED TO SERVICE.