What was found
FLAP CAUTION LIGHT WENT OFF 2 TIMES. RT FLAP INDICATOR MOVE DOWN, FLAP CAUTION LIGHT ILLUMINATED. SPLIT FLAP INDICATION GREEN LIGHT ON. FLAPS TEST 1 PANEL, NO CONTROL PROBLEMS EMERGENCY LANDING JAN. VISUALLY VERIFIED FLAPS IN UP POSITION AND INDICATED AGREEMENT AND FOUND SAFE FOR 1 TIME FERRY FLIGHT FROM JAN TO MEM TO REPAIR FLAP SPLIT CAUTION MSG. R&R DUAL INDICATOR FLAP POSITION PN ON/OFF 522858. SN OFF 9809551 ON 9805739 PER AMM 27-53-10-4. OPS CHECK GOOD IAW 27-51-00-05.