SDR MALA030326

Service difficulty report · Pump · Bac AVRO146RJ85A

Difficulty date
July 3, 2003
Submitted
July 8, 2003
Operation
Air carrier
Aircraft
N536XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2372
Part
Pump
Part number
521449
Part serial
GOO1OO70
Condition
Failed
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING FLIGHT 3478, DURING CRUISE AT 29000 FT THE YELLOW HYD HIGH TEMP LIGHT ILLUMINATED. FOLLOWED THE QRH AND SOME TIME AFTER TURNED OFF THE NR 2 ENG PUMP AC PUMP, AND THE PTU, THE HIGH TEMP ANNUNCIATOR WENT OUT. AIR RETURN TO DTW. MAINTENANCE REMOVED AND REPLACED NR 2 EDP IAW RJ85 MM 29-10-17. P/N ON OFF 521449, S/N ON F9717007, S/N OFF GOO1OO70. RAN SYSTEM FOR APPROX 1 HOUR, NO FAULTS NOTED. ALL CHECKS GOOD AT THIS TIME.